Manufactured in Malaysia since 2005 · SIRIM · MyHIJAU · SPAN certified · Shop online →
The Waterproofing System

How a Bina waterproofing system is built — layer by layer.

Waterproofing is a system, not a single coat. From a sound substrate through crack repair, primer and the membrane coats to a protective finish, each layer does a job. Here is exactly how the two main Bina systems are built — a flexible liquid membrane and a bonded cementitious slurry — with the manufacturer specs.

Liquid & cementitious systemsPositive-side applicationFor concrete, masonry & metalExposed & covered
The Build-Up

Two systems, layer by layer

Liquid membrane build-up (Multiproof 5000)

5
Protection / finishOptional screed, tiles or topcoat
optional
4
Membrane top coatMultiproof 5000 — 2nd elastomeric coat
1 kg/m²
3
Reinforcement at cracks/detailsGlass-fibre mat between coats
as needed
2
Membrane base coatMultiproof 5000 — 1st elastomeric coat
1 kg/m²
1
PrimerMultiproof diluted 20% water
1 coat
0
SubstrateCured concrete / metal / masonry — repaired
base

Cementitious build-up (Flexseal 2000 / Binaseal 1000)

4
Tile / screed (wet areas)Bonded directly over the slurry
optional
3
Slurry coat 2Flexseal/Binaseal — cross direction
1–2 kg/m²
2
Slurry coat 1Flexseal/Binaseal — rubbed in
1–2 kg/m²
1
SBR primer + pre-soakSurface dampened, no ponding
1 coat
0
Substrate + crack/honeycomb repairBina N.S. Grout / Bina Plug 4000
base

Read top-to-bottom as built on site. Layer counts and coverage follow the product datasheet and the site condition.

Stage 1 — Get the Base Right

Surface preparation

The system is only as good as what it sits on. Preparation differs by substrate and condition.

Sound

Sound & clean

Substrate must be sound, clean and free of dirt, dust, grease, oil and laitance. Repair honeycomb and cracks first.

Stop

Stop active leaks

Active running leaks are plugged with Bina Plug 4000 before any membrane is applied.

Prime

Prime & pre-soak

Cementitious systems are pre-soaked and SBR-primed; liquid membranes get a diluted priming coat.

Which System

Match the system to the requirement

Match the system to the requirement
RequirementRecommended system
Large flat roof / deck, heavy-duty, exposedTorchseal
Exposed roof / gutter / metal, flexible, recoatableMultiproof 5000
Wet areas, tanks, basements — under tile/screed, breathableFlexseal 2000
Tanks / reservoirs, high-strength, honeycomb repairBinaseal 1000
Active running leak — stop it nowBina Plug 4000
Technical Specifications

The numbers, straight from the datasheet

Real manufacturer data for two core systems. Full TDS for all five on the downloads page.

Bina Torchseal
TypeAPP-modified bitumen membrane, polyester reinforced
Softening point (ASTM D36)155 °C
Cold flexibility (ASTM D5147)0–4 °C
Tensile strength (ASTM D5147)Longitudinal 840 N/5cm · Transverse 720 N/5cm
Elongation @23°C45% (L & T)
Tear resistanceL 400 N · T 350 N
Heat resistance (110°C, 2 hr)No flow
Water absorption (24 hr)< 0.1% wt
Nominal weight / thickness3 or 4 kg/m² · 3 or 4 mm
Roll size1 × 10 m
Coverage1.15 m²/m² per layer (10cm side / 15cm end laps)
FinishesBlack smooth / mineral granule / sanded
StandardsASTM D6222 Type II · UEAtc · CGSB 37-GP-56M · DIN 52133
Bina Multiproof 5000
TypeWater-based 1-component elastomeric acrylic
FinishSatin
ColoursGrey, White, Dark Blue, Red Oxide, Green Oxide
Recommended DFT500 microns
Coverage1 kg/m² per coat
No. of coats2–3 coats
Ultimate elongation300%
Tensile strength7 N/mm²
DryingTouch dry 45 min · recoat 3 hr · cure 48 hr
Pack size1, 5, 20 kg
Thinner / cleanerClean water
The Install

Method statement (warranty-grade)

01

Inspect & diagnose — identify the leak source, substrate and movement; agree the system.

02

Repair & stop leaks — cut out defects, fill honeycomb with grout, stop active leaks with Bina Plug 4000.

03

Prepare & prime — clean to a sound surface, form fillets at upstands, pre-soak/prime per system.

04

Apply the membrane — minimum two coats, reinforcing cracks and details; observe recoat and cure times.

05

Test & protect — flood/ponding test where applicable, then protect (screed/tiles) and issue warranty.

Waterproofing FAQ

Common questions

What’s the difference between a liquid membrane and a cementitious slurry?

A liquid acrylic membrane (Multiproof 5000) stays flexible and bridges movement cracks — ideal for exposed roofs, gutters and metal. A cementitious slurry (Flexseal 2000 / Binaseal 1000) bonds to concrete and can be tiled or screeded over — ideal for wet areas, tanks and basements.

Which side do you waterproof — inside or outside?

Wherever possible, waterproofing is applied to the positive (water-facing) side so hydrostatic pressure presses it onto the substrate. For basements that means the external face; for tanks, the wet face.

Can you stop a leak that’s actively running?

Yes. Bina Plug 4000 is a chloride-free hydraulic plug that sets in seconds to stop running water, so the surface can be dried and the membrane system applied.

How long is the warranty?

Up to 10 years on qualifying systems applied by Bina-trained applicators. The exact term depends on the system and the conditions — we confirm it with the specification.

Do you provide datasheets for tenders?

Yes — published TDS for every system, plus guide specifications and method statements on the specs & downloads page.

Proof

Trusted on real waterproofing projects

Bina-manufactured systems, applied by our own teams on roofs, tanks and structures across Malaysia.

Bina waterproofing project - Torch-on membrane, rooftop plant
Torch-On

Torch-on membrane, rooftop plant

Bina-manufactured, Bina-applied
Bina waterproofing project - Institutional building, sealed roof
Institutional

Institutional building, sealed roof

Bina-manufactured, Bina-applied
Bina waterproofing project - Pools & water-retaining structures
Pool / Tank

Pools & water-retaining structures

Bina-manufactured, Bina-applied

Want this system specified for your project?

Send us your surface, area and site condition. We’ll recommend the right system and quote design, supply and application in one package.

Manufacturer-grade systems
Real datasheets & method statement
Approved-applicator workmanship
Get a quote on WhatsAppSpecs & downloads